FAM-01
Rack power distribution units
Made by AmpRack · Group A
Product category · Group A · data centre & compute infrastructure
Seven supplier sites build the power chain of an AI rack — busway, outlet, battery, supply, coupling. One contract.
01Connection layer · what we supply
FAM-01
Made by AmpRack · Group A
FAM-02
Made by VoltBridge · Group A
FAM-03
Made by CapStack · Group A
FAM-04
Made by TitanWatt · Group A
FAM-05
Made by VoltFab · Group A
FAM-06
Made by RackForge and DryLink · Group A
02Connection layer · who builds it
AI data-centre power system EMS, burn-in tested under one quality system.
UL 62368-1 · UL 1973 · UL 9540A · UL 857 · IEC 61439-6 · 80 PLUS Titanium
CRPS, CRPS 1600–2400 W and M-CRPS toward GPU power and shelves.
IEC/UL/EN 62368-1 · CB scheme · FCC Part 15 Subpart B
BBU battery backup units bridging power excursions in milliseconds.
UN 38.3 tested · IEC 62619 · CE · EU 2023/1542
Metered, switched and outlet-metered rack PDUs on their own PCBA line.
UL 62368-1 · IEC 60309 · IEC 62053-21 · FCC Part 15 A · ISO 9001
LIC hybrid supercapacitor modules for server backup and industrial ride-through.
UL 810A cell route · IEC 62391 · UN 3499 shipping documents
AI racks and cold-aisle containment off their own sheet-metal line.
EIA-310-E · IEC 60297 · GR-63 Zone 4 optional · ISO 9001
OCP-compliant UQD quick disconnects and rack manifolds, machined in-house.
OCP UQD interface compliance · ISO 4406 cleanliness · ISO 9001
Every unit here is a populated assembly underneath, and our own PCB & PCBA factory is our engineering baseline.
Read from each site's own published list, 2026-09-13
03Decision layer · choose by requirement
REQ-01
A 10 A C13 outlet at 250 V is a 2.5 kW interface. Connector, PDU, busway and shelf re-specify together.
Source AFCOM State of the Data Center Report via Upsite
REQ-02
Where cycle life matters more than stored energy, the supercapacitor tier is the cheaper answer.
Governing site VoltBridge · CapStack
REQ-03
80 PLUS Titanium for 230 V internal-redundant server PSUs; Ruby released 2025-03-12.
Governing site TitanWatt
REQ-04
The leak-test report ships in the carton, per unit, rather than as a batch statement.
Governing site DryLink
04Trust layer · standards
48 VDC busbar, 18 kW per rack standard and 30 kW liquid-cooled. Rack height 2,286 mm (44 OpenU), 1,400 kg maximum load.
One published example rates the same PC/ABS material V-2 at 0.4–0.5 mm, V-1 at 0.6 mm and V-0;5VA at 3.0 mm. Quote the thickness.
The safety baseline for server power, PDUs and IT equipment. The 4th edition drops acceptance of components certified to IEC 60950 or IEC 60065, which reaches into the PSU supply chain.
C13/C14 is rated 10 A / 250 VAC internationally and C19/C20 16 A. Listed covers a complete product; Recognized covers a component.
05Execution layer · how we carry it
SVC-01
Seven sites, one wrong match.
We read the load profile, then place the order with the site that publishes the number your tender asks for.
SVC-04
A datasheet that does not survive your rack.
Written by engineers: derating, connector ratings, coolant compatibility and the gap to your specification.
SVC-05
The shipped batch is not the sampled batch.
Pre-shipment inspection to ISO 2859-1 general level II, critical defects accepted at zero.
SVC-06
A rack and a battery leave under different paperwork.
FOB by default, FCA for inland stuffing, CFR or CIF when we sell the freight.
06Inputs · what to send us
07Start
Name the family or attach the drawing, and we will say which of the seven sites fits.
Written technical assessment, from eric@dfshk.cn.
Start · short form
One line is enough to start. An engineer answers, not a chatbot.
We answer from eric@dfshk.cn. If you have a drawing or a spec sheet, reply to that message and attach it.